RMC Non Contact
+44 (0)345 00 00 400
[email protected]
Menu

RMC Coded Magnetic Non Contact

 

IDEM Safety SwitchesThe IDEM RMC Hygiecode - Coded Non Contact

  • Coded magnetic auction
  • Sensitivity at recommended 4mm setting
  • Wide 10mm sensing - low hysterisis - no moving parts
  • 2NC & 1NC circuits
  • Can be flush mounted - Solid Stainless Steel 316 housing

The IDEM hygiecode coded non contact RMC switch is a cylindrical fitting which is suitable for all industry applications. It is easy to install with a M30 threaded body and easy to set and it has a wide 10mm sensing low hysteresis with no moving parts. It has been designed with a 10mm switching tolerance and stainless steel housing which is suitable to harsh environments for food processing and packaging. The RMC has a quick connect M12 versions which are fitted with 150 (10”) cable and IP69K tested for high pressure hosing with detergent at 80C and 100PSI.

The IDEM RMC has three switches connected in series to an SCR-2 or SCR-3 to give dial channel guarding monitoring manual start and contactor feedback check as well as LED indication and flush mounted with solid stainless steel 316 housing. With coded magnetic auction and sensitivity recommended at 4mm setting this RMC coded non contact switch is suitable for any industry.

The IDEM RMC has 1NC & 1NO circuits with safety protections up to: PLe ISO 13849-1 EN 62061 Cat 4 EN 954-1

 

RMC Non Contact Main Features


Standards EN1088 IEC 60947-5-3 EN 60204-1 ISO 13849-1 EN62061 EN 954-1 UL 508
Safety classification and reliability data
Switching reliability 3.3 x 106 operations at 100mA load
EN 954-1 Up to category 4 with safety relay
ISO 13849-1 Up to PLe depending upon system architecture
EN 62061 Up to SIL3 depending upon system architecture
Safety data - Annual usual 8 cycles per hour / 24 hours a day / 365 days
PFHd 2.52 x 10-8
Proof test interval (life) 47 Years
MTTFd 470 Years
Safety Channel 1 NC 24V.dc 0.2A Max. rating
Safety channel 2 NC 24V.dc 0.2A Max. rating
Safety channel 3 NO 24V.dc 0.2A Max. rating
Minimum switched current 10V.dc 1mA
Dielectric withstand 250V.ac
Insulation Resistance 100 Mohms
Recommended setting gap 5mm
Switching distance Sao 8mm close
Target to target Sar 12mm open
Tolerance to misalignment 5mm in any direction from 5mm setting gap
Switching frequency 1.0Hz minimum
Approach speed 200mm/m to 1000mm/s
Body material Stainless steel 316 Mirror polished finish (Ra4)
Temperature Range -25 + 105C
Enclosure Protection IP69K IP67
Shock resistance IEC 68-2-27 11ms 30g
Vibration resistance IEC 68-2-6 10-55 Hz 1mm
Cable type PVC 6 or 8 core 6mm O.D
Mounting bolts 2 x M4 Tightening torque 1.0 Nm