KPC Non Contact
+44 (0)345 00 00 400
[email protected]
Menu

KPC Coded Magnetic Actuation Non Contact

IDEM Safety SwitchesIDEM KPC coded magnetic actuator switching tolerance up to 10mm The IDEM KPC has plastic housing offering both Front and End Actuation and will operate with most safety relays.

Application

IDEM KPC coded non contact safety switches are designed to fit to hinged, sliding or removable guard doors. They have an industry standard fixing and are especially advantageous when:

(a) Sever guard alignment exists - using traditional tongue types versions
(b) Long mechanical life is required (no moving or touching parts)

When used in combination with dual channel safety relays the IDEM KPC can be used to provide up to PLe ISO 13849-1, SIL3 EN62061 and Cat. 4 EN 954-1.

Featuring industry housing shape: 52mm wide, 98mm long and 40mm fixing. Fully encapsulated sealing and pre-wired 2m, 5m or 10m cable.

2NC 1NO semi-conductor outputs for connection to safety relay.

Visual LED indication of switch status.

M12 8 way Quick Connect version - flying lead 150mm.


KPC Main Features

Standards: EN1088 IEC 60947-5-1 EN60204-1
ISO 13849-1 EN62061 EN954-1 UL508
Safetey Classifiaction and Reliability Data  
Switching Reliability 3.3x 106 operations at 100mA load
EN954-1 up to Category 4 with Safety Relay
ISO 13849-1 up to PLe depending upon system architecture
EN 62061 up to SIL3 depending upon system architecture
Safety Date - Annual Usage 8 cycles per hour / 24 hours per day / 365 days
PFHd 2.52 x 10-8
Proof Test Interval (Life) 47 years
MTTFd 470 years
Safety Channel 1 NC 24V.dc 0.2A Max Rating
Safety Channel 2 NC 24V.dc 0.2A Max Rating
Safety Channel 3 NO 24V.dc 0.2A Max Rating
Minimum switched current 10V.dc 1mA
Dielectric withstand 250V.ac
Insulation Resistance 100Mohms
Recommended setting gap 5mm
Switching Distance Sao 8mm Close
(Target to target) Sar 20mm Open
Tolerance to misalignment 5mm in any direction from 5mm setting gap
Switching Frequency 1.0 Hz maximum
Approach Speed 200mm/m to 1000mm/s
Body Material UL approved polyester
Temperature Range -25 +80C
Enclosure Protection IP67 (NEMA 6)
Shock Resistance IEC 68-2-27 11ms 30g
Vibration Resistance IEC 68-2-6 10-55Hz 1mm
Cable type PVC 6 or 8 core 6mm O.D
Mounting Bolts 2 x M5 Tightening torque 1.0Nm
Mounting Position Any

For more information about IDEM KPC coded non contact KOBRACODE Switches, contact More Control on 0345 00 00 400.

Office Address 

21 Drakes Mews
Crownhill Industrial Estate
Milton Keynes
MK8 0ER

Tel: 0345 00 00 400

Email: This email address is being protected from spambots. You need JavaScript enabled to view it.

Search Website